Cart  

product (empty)

Manufacturers

Advertising

TIME TUD300 Ultrasonic Flaw Detector

TIME TUD300 Ultrasonic Flaw Detector
Equipped with gate setting and alarming function. Freeze/defreeze waveform and detection parameters; Communicating with PC by RS232 port for transferring the measuring data and system parameters; Provided with linear suppressing function, the highest suppressing is 80% of the screen height; Memory up to 300 A scanned images, parameters and DAC, and 30000 thickness values.

More details

$6,120.00 tax incl.

Availability: Shipping to Worldwide

Add to cart

Product info:

 

  • Measuring of pitch interval and analyze of echo times;
  • Two input methods: angles and K value.
  • Auto-calibration of probe and auto-gain.
  • Two measuring unit: mm/inch;
  • All built-in software can be up-graded on PC;
  • Lock/unlock the system parameters;
  • Equipped with gate setting and alarming function.
  • Two measurement displaying mode: type A and type B;
  • Freeze/defreeze waveform and detection parameters;
  • Communicating with PC by RS232 port for transferring the measuring data and system parameters;
  • 10 detecting channels are available with a separate detecting parameter and DAC curve in every channel.
  • Automatic generation of DAC curve, and 30 points can be recorded at most, adjustable offset curves and gain correction functions are available.
  • Provided with linear suppressing function, the highest suppressing is 80% of the screen height;
  • Memory up to 300 A scanned images, parameters and DAC, and 30000 thickness values.
  • Four Rectify Ways: positive half-wave, negative half-wave, full wave and radio frequency.
  • Three detecting modes: single-probe , dual-probe ones and transmission;

 

Specification:

 

  • Scanning Range: 2.5 mm ~9999 mm
  • Scanning Resolution: 0.1mm (2.5mm ~100mm) 1mm (100 mm ~5000mm)
  • Gain Range: 0dB ~110 dB
  • D-Delay: -20μs~+3400μs
  • P-Delay: 0μs~99.99μs.resolution 0.01μs
  • Sound speed: 1000 m/s~9999m/s
  • Bandwidth: 0.2MHz~15MHz(Low0.2~1,Mid.0.5~4, High 3~15)
  • Vertical linearity error: ≤3%
  • Horizontal linearity error: ≤0.2%
  • Dynamic range: ≥32dB
  • Rectification: Positive half wave, negative wave, full wave, and RF
  • Sensitivity leavings: ≥60dB
  • Test mode: Pulse-echo, dual and through transmission 
  • Pulser: Spike excitation pulser
  • Damping: 50ohms, 150ohms and 400ohms
  • Reject: Linear, 0-80% of full screen, variable in steps of 1%
  • Unit: Metric/inch
  • Interface: RS232/USB
  • Printer: EPSON inl-jet printer
  • AC requirements: 85-264V AC/1.0A,47-63Hz
  • Temperature: -10°C~40°C
  • Humidity: 20%~90%RH
  • Power supply: Li battery 4x3.6V 4000mAh
  • Charging time: 4~5hours
  • Weight: 1.47kg
  • Overall dimension: 243mmx173 mmx70 mm 

Specials

  • $0.00 $0.00

PayPal